E-mail: james@felixglass.com - Tel: +86 185 6503 2888
Home / Products / Infrared Optical Components / ZnSe Lenses
Home / All / Display & Functional Glass / Medical display glass / Anti-Glare Medical Display Glass for Medical Imaging & Touch Systems

Looking for Custom Optical Components?

✔ OEM / ODM Customization

✔ Free Drawing DFM Technical Review

✔ 24-Hour Professional Quotation

✔ Flexible Low MOQ & Fast Prototypes

Anti-Glare Medical Display Glass for Medical Imaging & Touch Systems

Anti-Glare Medical Display Glass for Medical Imaging & Touch Systems
Anti-Glare Medical Display Glass for Medical Imaging & Touch SystemsAnti-Glare Medical Display Glass for Medical Imaging & Touch SystemsAnti-Glare Medical Display Glass for Medical Imaging & Touch SystemsAnti-Glare Medical Display Glass for Medical Imaging & Touch SystemsAnti-Glare Medical Display Glass for Medical Imaging & Touch SystemsAnti-Glare Medical Display Glass for Medical Imaging & Touch Systems
Share
CategoriesMedical display glass
BrandFELIX GLASS optical glass Manufacturing base
ModelFG‑MED‑AG‑005
SubstrateMedical-grade low-iron biocompatible tempered glass
Coating OptionsAG / AG+AR / AG+AF / AG+AR+AF
Visible Transmittance≥92%, AR coated up to 97%
AG Adjustable Haze5%–10% (medical low-haze grade for clear imaging)
AF Water Contact Angle≥110°
Surface Hardness9H Mohs scratch resistance
Common Thickness1.1mm, 2.0mm, 3.0mm
Disinfection ResistanceTolerate alcohol, hydrogen peroxide repeated wiping
Working Temperature-20°C ~ 120°C
Custom ProcessingCNC cutting, full edge chamfering, black border silk printing, sensor hole drilling
ComplianceISO 9001, RoHS, REACH, ISO 10993 biocompatible
Unit PriceUS $ 7.53-9.89 / piece
FOB portSHENGZHEN SHANGHAI GUANGZHOU
Terms of PaymentL/C, D/A, D/P, Western Union
DownloadDownload pdfDownload pdfDownload pdfDownload pdfDownload pdf
Detail Information

Anti-Glare Medical Display Glass for Medical Imaging & Touch Systems

Felix Glass anti-glare medical display glass is professional protective cover glass specially developed for clinical medical imaging and touch monitoring devices. Made of biocompatible low-iron tempered glass with precision AG anti-glare matte coating, it effectively eliminates ambient light reflection in wards and operating rooms. Optional AR anti-reflection and AF anti-fingerprint coatings are available to match strict medical hygiene and high-definition imaging demands. All glass meets hospital long-term disinfection and long-hour viewing requirements.

Core Coating Functions

AG Anti-Glare

Uniform micro matte etching diffuses harsh operating lamp and ward light glare, removes mirror reflection to avoid interfering doctor’s image judgment during diagnosis.

Optional AR Anti-Reflection

Boost light transmittance up to 97%, restore true color of CT, ultrasound and X-ray imaging screens for accurate medical analysis.

Optional AF Anti-Fingerprint

Hydrophobic oleophobic nano coating repels fingerprints and medical disinfectant residues, one wipe clean for frequent clinical touch operation.

Coating Combination Selection Guide

  • AG Only: General ward patient monitors
  • AG + AR: High-precision medical imaging diagnostic screens (ultrasound, radiology equipment)
  • AG + AF: Multi-person shared touch medical terminals
  • AG + AR + AF Triple Coating: Operating room high-end surgical display screens

Technical Specifications

PropertyStandard Parameter
SubstrateMedical-grade low-iron biocompatible tempered glass
Coating OptionsAG / AG+AR / AG+AF / AG+AR+AF
Visible Transmittance≥92%, AR coated up to 97%
AG Adjustable Haze5%–10% (medical low-haze grade for clear imaging)
AF Water Contact Angle≥110°
Surface Hardness9H Mohs scratch resistance
Common Thickness1.1mm, 2.0mm, 3.0mm
Disinfection ResistanceTolerate alcohol, hydrogen peroxide repeated wiping
Working Temperature-20°C ~ 120°C
Custom ProcessingCNC cutting, full edge chamfering, black border silk printing, sensor hole drilling
ComplianceISO 9001, RoHS, REACH, ISO 10993 biocompatible

Key Features

  • Medical Low-Haze AG Coating: Balances anti-glare performance and imaging definition without distorting medical images
  • Biocompatible Tempered Substrate: Safe for clinical environment, no harmful precipitation
  • Disinfection Resistant Coatings: No peeling or performance loss after daily hospital sterilization
  • 9H Hardness Anti-Scratch: Resist collision and scratch during frequent ward use
  • Fully Customizable Appearance: Custom outline, black printed border and reserved holes for medical equipment assembly

Applications

Ultrasound diagnostic touch screens, radiology medical imaging monitors, surgical operating room displays, ward patient monitoring terminals, ophthalmic detection equipment, in-vitro diagnostic touch control panels.

Custom Manufacturing Services

  • Custom glass size, thickness and irregular shapes according to medical device drawings
  • Flexible AG/AR/AF coating combinations for different clinical scenarios
  • Silk screen black border, LOGO printing and precision sensor hole machining
  • Small-batch prototype trial and mass production for medical equipment manufacturers
  • Complete biocompatibility and optical performance test reports supplied

Why Choose Felix Glass

Specialized medical optical glass manufacturer focused on hospital display protective glass. All medical AG glass passes ISO 10993 biocompatibility testing, with independent medical coating workshop. Each product undergoes full inspection of haze, transmittance and coating stability before delivery. Our engineers provide professional coating matching suggestions for diagnostic and surgical medical equipment, supporting global delivery for medical device factories.

FAQ

Which coating combination is best for ultrasound imaging screens?
AG + AR combination, anti-glare for ward light while ensuring high-definition medical imaging.

Can AG coating withstand repeated medical alcohol disinfection?
Yes, dense magnetron sputtered coating resists long-term disinfectant wiping without failure.

Is this glass safe for clinical medical environments?
The substrate meets ISO 10993 biocompatibility standards, non-cytotoxic and safe for hospital use.

Can you customize printed black borders for medical displays?
Custom silk screen printing, edge chamfering and precision drilling are fully supported.

Get a Free Quote

Provide your glass size, thickness, coating demands and processing requirements. Our engineering team will offer customized pricing, qualified samples and medical-grade test documents within 24 hours for your medical imaging equipment projects.

Need Custom Optical Glass Solution?

Send us your drawing, dimension & coating requirements for fast quotation within 24 hours.

Get Free RFQ

Custom Precision Optical & Glass Components Manufacturer – Felix Glass Co., Limited.

We supply Industrial Glass, Sapphire Optics, Optical Lenses/Prisms/Filters, Infrared IR Optics, Functional & Display Glass, N-BK7/H-K9L Optical Glass, supporting OEM mass production and laboratory custom prototypes. Flexible MOQ & free sample service available. Fill in the form to download full datasheets and get factory wholesale price within 24 hours.

CONTACT US NOW FOR A QUOTE
Send an inquiry now—we will respond promptly within 1–24 hours and provide our best formal quote within 1–2 days! Let’s start a mutually beneficial partnership today...
*Email
Name
*Title
*Content
Learn more from our FAQ
What is your MOQ for custom optical glass and display glass parts?

Felix Glass offers highly flexible MOQ to support client projects, including prototype testing, small batch trial orders and large-volume mass production. All products can be fully customized according to your drawings, tolerances and application standards. Send us your specs to get an accurate price quote within 24 hours.

Can I get free glass samples for testing before bulk order?

Yes, our FELIX GLASS factory supports sample testing for a wide range of precision optical glass components and assemblies. The lead time for sample production is 3 to 7 working days. Please contact us today to arrange samples and obtain a customized solution that meets your needs.

What is the production lead time for custom optical glass components?

What is the production lead time for custom optical glass components?
Answer: The lead time for standard samples is 3–7 business days, while mass production takes 15–25 business days, depending on product complexity and order volume. We provide reliable, rapid delivery for orders serving the industrial, medical, automotive, and aerospace sectors. Please submit your project details to receive an accurate delivery schedule.

Are your optical glass products ISO, CE and RoHS certified?

All FELIX GLASS precision optical glass components comply with ISO quality system standards, as well as CE and RoHS requirements. We provide comprehensive test reports, material certificates, and inspection documentation for customer review. Please feel free to request full certification details and a formal quotation today.

Do you offer one-stop custom optical glass processing services?

Yes. We provide a full range of in-house processing services, including CNC machining, precision grinding, optical polishing, vacuum coating (AR, AF, AG, IR), tempering, and screen printing. Every step—from raw material to finished product—is carried out within our own facility. Please let us know your requirements, and we will provide you with the most cost-effective solution.

CONTACT US NOW FOR A QUOTE
Send an inquiry now—we will respond promptly within 1–24 hours and provide our best formal quote within 1–2 days! Let’s start a mutually beneficial partnership today...
*Email
Name
*Title
*Content

 

A specialist in precision optical glass with 19 years of experience, providing comprehensive, satisfying custom solutions.


Navigation
News